Skip to main content
BSA 2022 // RRO 2005 READY
+44 (0) 20 7946 0912
VANGUARD.Statutory Fire Engineering
INSPECTOR CONSOLE // STATUTORY MATRIX

UK Commercial Statutory Compliance Matrix

Inspect statutory review cycles, Dutyholder responsibilities, and British Standard deliverables prior to your next Fire & Rescue Service or BSR audit.

Estimate Audit Scope →
Engineer conducting industrial fire sprinkler valve hydraulic flow diagnosticBS EN 12845 // HYDRAULIC

Sprinkler Valve & Flow Telemetry

Weekly churn & quarterly flow proof

Fire compliance engineer testing main control panel and addressable loop voltage telemetryBS 5839-1 // ADDRESSABLE

Control Panel & Loop Voltage

6-monthly cause-and-effect audit

Emergency luminaire lux-meter photometric reading and escape route illumination inspectionBS 5266-1 // PHOTOMETRIC

Emergency Lighting 3-Hr Drain

Annual lux-meter escape route log

7 entries
Code / StandardStatutory RequirementReview CycleDeliverableStatus
RRO 2005 // Art. 9

Suitable & Sufficient Fire Risk Assessment (PAS 79-1)

All Non-Domestic & Common Parts · Responsible Person (Employer / Managing Agent)

Annual Review / Material ChangeBAFE SP205 Certified FRA & Prioritised Action PlanMandatory
BSA 2022 // Part 4

Golden Thread Digital Safety Case & Accountable Person Logs

HRB 18m+ or 7+ Storeys (2+ Residential Units) · Principal Accountable Person (PAP)

Continuous / BSR Gateway UpdatesImmutable Digital Safety Case & Resident Engagement LogCritical
BS 5839-1:2017

Commercial Fire Detection & Fire Alarm Servicing

L1–L5 & M Commercial Categories · Responsible Person / Facilities Lead

6-Monthly (Minimum) + Weekly User Call-Point TestCause-and-Effect Verification & FIA Inspection CertificateMandatory
BS 5266-1:2016

Emergency Escape Lighting Duration & Lux Verification

All Escape Routes, Open Areas & High-Risk Tasks · Dutyholder / Building Operations

Monthly Flick Test + Annual 3-Hour Drain Test3-Hour Full Duration Certificate & Lux Level ScheduleStatutory
BS EN 12845 / LPC

Automatic Sprinkler Pump Churn, Valve & Tank Diagnostics

Commercial Warehousing, Retail & HRB Suppression · Building Owner / FM Contractor

Weekly Pump Test + Quarterly / Annual Hydraulic AuditPressure-Flow Curve & LPC Sprinkler Compliance ReportCritical
RRO 2005 // Art. 17 & Reg 10

Fire Door & Passive Compartment Penetration Inspection

FD30S / FD60S Doorsets & Service Risers · Responsible Person / Accountable Person

Quarterly (HRB Common Doors) / Annual (Commercial)Pin-Indexed Door Schedule & Intumescent Seal AuditMandatory
BS 9999 / TR19

Smoke Control, Dampers & Kitchen Extract Duct Hygiene

Atriums, Basement Car Parks & Commercial Kitchens · Commercial Landlord / Catering Operator

Annual Damper Drop Test + 6-Monthly TR19 CleanAirflow Velocity Log & BESA TR19 Grease Thickness CertificateStatutory